Overview
The IDP HVAC Type F Insulated Line Set is a pre-insulated copper tubing assembly for mini-split AC and heat pump systems. 3/8″ liquid line paired with 5/8″, 3/4″ or 7/8″ suction line, 3/8″/1/2″/3/4″ closed-cell PE foam insulation, in 30ft and 50ft lengths. Supplied without flared nuts for field-flaring.
Key Features
- Annealed copper tubing, clean ends ready to flare
- 3/8″ liquid line, suction sizes: 5/8″ / 3/4″ / 7/8″
- Insulation thickness: 3/8″, 1/2″, 3/4″
- Lengths: 30ft and 50ft
- Without flared nuts (nuts & ferrules sold separately)
- 12 models covering all tube/insulation/length combinations
Specifications
| Model (SKU) | Tube Size (Liquid x Suction) | Insulation | Length |
|---|---|---|---|
| F385812030 | 3/8″ x 5/8″ | 1/2″ | 30ft |
| F385812050 | 3/8″ x 5/8″ | 1/2″ | 50ft |
| F383438030 | 3/8″ x 3/4″ | 3/8″ | 30ft |
| F383438050 | 3/8″ x 3/4″ | 3/8″ | 50ft |
| F383412030 | 3/8″ x 3/4″ | 1/2″ | 30ft |
| F383412050 | 3/8″ x 3/4″ | 1/2″ | 50ft |
| F383434050 | 3/8″ x 3/4″ | 3/4″ | 50ft |
| F387838030 | 3/8″ x 7/8″ | 3/8″ | 30ft |
| F387838050 | 3/8″ x 7/8″ | 3/8″ | 50ft |
| F387812030 | 3/8″ x 7/8″ | 1/2″ | 30ft |
| F387812050 | 3/8″ x 7/8″ | 1/2″ | 50ft |
| F387834050 | 3/8″ x 7/8″ | 3/4″ | 50ft |
Model Number Decoding
Example F385812050: F = Type F · 38 = 3/8″ liquid · 58 = 5/8″ suction · 12 = 1/2″ insulation · 050 = 50ft.
Compatible With
Mini-split and ductless heat pump systems 9k–36k BTU. Match tube size and insulation thickness to your outdoor unit nameplate; field-flare and trim to length on site.
Installation Notes
- Without flared nuts — flare ends on-site with a proper flaring tool; follow torque specs.
- Trim to exact length after dry-fitting; measure total run before cutting.
- Inspect insulation jacket for damage before installation; repair any tears.
- Custom-cut or opened line sets are non-returnable per our Terms.
FAQ
Q: Does this include flared nuts?
A: No. Standard plain-end version; nuts and ferrules are sold separately.
Q: What insulation thickness do I need?
A: Choose 3/8″ / 1/2″ / 3/4″ based on your climate and local code; thicker insulation for humid or high-ΔT runs.
Q: Lengths available?
A: 30ft and 50ft, in 5/8″, 3/4″ and 7/8″ suction sizes.

Reviews
There are no reviews yet.